As printed on the label.
Parity layouts only. Drives are split evenly.
We recommend at least 20.

Usable capacity

-

-

  • Raw capacity -
  • Spent on redundancy -
  • Space efficiency -
  • Comfortable capacity -
  • Survives -

Estimates exclude filesystem metadata, padding and reserved space, which usually cost a few percent more.

Reading the results

  • Usable capacity is shown in TiB, the binary units most operating systems display, with the decimal TB figure underneath. A 12 TB drive appears as about 10.9 TiB.
  • Comfortable capacity subtracts the free space you choose to keep. Copy-on-write filesystems slow down and fragment as they approach full, so plan to stay below about 80 percent.
  • Survives describes guaranteed fault tolerance. With several groups, you may survive more failures if they land in different groups, but you cannot count on it.

Choosing a layout

LayoutBest forTrade-off
Two-way mirrorsVM storage, databases, small pools, easy growth two drives at a timeHalf the raw space goes to redundancy
Single paritySmall drives, or data fully backed up elsewhereNo protection left during a long rebuild
Double parityBulk storage on large drivesTwo drives per group go to parity
Triple parityVery wide groups and archivesThree drives per group go to parity
StripeScratch data you can loseAny drive failure loses everything

Splitting drives into more groups improves performance and shortens rebuilds, at the cost of more parity. Twelve drives as two six-wide double-parity groups give up four drives to parity but perform and rebuild noticeably better than one twelve-wide group. More detail in ZFS and Filesystems.

Worked examples

  • Six 12 TB drives, double parity, one group: 48 TB usable, about 43.7 TiB, about 34.9 TiB comfortable. This is our Closet Lab pool.
  • Twelve 16 TB drives, double parity, two groups: 128 TB usable, about 116.4 TiB, about 93.1 TiB comfortable. This is our Rack Lab pool.
  • Two 8 TB drives, two-way mirror: 8 TB usable, about 7.3 TiB, about 5.8 TiB comfortable. This is our Shelf Lab pool.

Caution

Capacity is only half the plan. Redundancy keeps a pool running when drives fail; it does not protect against deletion, ransomware, fire or theft. Budget for backup storage at the same time. See Backup Strategy.